System Based on the Technique of Spectroscopy for Measurement of Bioimpedancias for Samples in Tissues of Fish

dc.contributor.authorIglesias Gamarra, José Ramón
dc.contributor.authorRodríguez Alvarez, Omar
dc.contributor.authorMacías Cifuentes, Edson
dc.contributor.authorCabrera Durán, Eduardo
dc.contributor.authorDaza Orsini, Sandra Milena
dc.date2015-07-01
dc.descriptionThe project described in this paper is the first part of the research conducted by MAGMA Engineering research team of the electronic engineering program at Universidad del Magdalena, Colombia, whose main research subject was quality control of process in the Centro Acuícola y Pesquero at this university through the determination of impedance patterns in fish in its early post-mortem phase to detect impedance levels of a species in decomposition or with a high level of tissue damage. This first part of the research was oriented to build a prototype capable of measuring the fish tissue impedance applying the impedance spectroscopy method in the range of 1ω to 100ω. The prototype consists mainly of two high-resolution frequency function generators capable of generating an arbitrary frequency in the range of 100hz to 500khz.  en-US
dc.descriptionEl proyecto presentado en este artículo fue la primera parte de la investigación realizada por el grupo de investigación MAGMA Ingeniería del programa de ingeniería electrónica de la Universidad del Magdalena, y en la cual se trabajó el control de calidad de los procesos en el Centro Acuícola y Pesquero de esta universidad a través de la determinación de patrones de impedancia en el pescado en su etapa post-mortem hasta detectar los niveles de impedancia de una especie en descomposición, o con un alto nivel de deterioro tisular.es-ES
dc.formatapplication/pdf
dc.identifierhttps://revistas.unilibre.edu.co/index.php/ingeniare/article/view/558
dc.identifier10.18041/1909-2458/ingeniare.17.558
dc.identifier.urihttp://hdl.handle.net/10901/15305
dc.languagespa
dc.language.isospaspa
dc.publisherUniversidad Librees-ES
dc.relationhttps://revistas.unilibre.edu.co/index.php/ingeniare/article/view/558/434
dc.relation/*ref*/O. Salah, “Espectrómetro de impedancia para monitoreo de daño isquémico tisular”. Tesis de Maestría en ciencia. México D.F.: Universidad Autónoma Metropolitana Unidad Iztapalapa.
dc.relation/*ref*/Departamento de Ciencias Básicas e Ingeniería, 1999.
dc.relation/*ref*/O. Salah. “Caracterización in-vivo de la espectrometría de impedancia como técnica de monitoreo del daño isquémico tisular”. Tesis Doctoral en Ingeniería Biomédica. México D.F.: Universidad Autónoma Metropolitana Unidad Iztapalapa. Departamento de Ciencias Básicas e Ingeniería, 2003.
dc.relation/*ref*/E. Gersing, “Measurement of electrical impedance in organs measuring equipment for research and clinical applications”, Biomedizinische Technik, Vol.36, pp.6-11, Jan. 1991.
dc.relation/*ref*/S. Grimnes and O. Martinsen, Bioimpedance and Bioelectricity Basics. 2 ed. Oxford U.K.: Elsevier, 2008.
dc.relation/*ref*/W. Ching-wei, “Electrical Impedance Tomography (E.I.T.) Measurement System”. Tesis de maestria. Cape Town.: University of Cape Town. Department of Electrical Engineering, 2003
dc.relation/*ref*/B.P. Lathi, Introducción a la teoría y sistemas de comunicación. 3 ed. México D.C.: limusa, 2005.
dc.relation/*ref*/J. PROAKIS and D. Manolakis, Tratamiento digital de señales. 4 ed. España: Pearson, 2007.
dc.relation/*ref*/BIBLIOGRAFIA DE CONSULTA
dc.relation/*ref*/• C. Jiménez y D. León, “Biosensores: Aplicaciones y perspectivas en el control y calidad de procesos y productos alimenticios”, Vitae, Revista De La Facultad De Química Farmacéutica, vol. 16, n°. 1, pp. 144-154, 2009.
dc.relation/*ref*/• L. Lopez, “Actividad Aminopetidásica Ligada A Membrana De Bacterias Gram-Negativas: Prueba De La P-Nitroanilina Para La Estimación De La Carga Bacteriana De Carne Picada”. Tesis doctoral. Madrid.: Universidad Computense de Madrid. Departamento de nutrición, Bromatología y tecnología de los alimentos, 2004.
dc.relation/*ref*/• R. Mcdonald, “Impedance Spectroscopy. University of North Carolina”, Annals of Biomedical Engineering, vol. 20, pp. 289-305, 1992.
dc.relation/*ref*/• C. Ramzi, “Patología funcional y estructural”. Compendio de Robbins y Cotran. 7 ed. Madrid Elsevier, 2008.
dc.relation/*ref*/• E. Sacristan, “Espectrómetro de impedancias para aplicaciones biomédicas”, en Memorias de II Cong. Lat. Ing. Biom., La Habana, 2001.
dc.relation/*ref*/• J. Semmlow, Biosignal And Biomedical Image Processing, Matlab Based Application. New York: Marcel Dekker,2004.
dc.relation.ispartofjournalRevistas – Ingenieríasspa
dc.rights.licenseAtribución-NoComercial-SinDerivadas 2.5 Colombia*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/co/*
dc.sourceIngeniare; No 17 (2014): INGENIARE; 11-30en-US
dc.sourceIngeniare; Núm. 17 (2014): INGENIARE; 11-30es-ES
dc.source2390-0504
dc.source1909-2458
dc.subjectAnálisis espectralspa
dc.subjectBioimpedanciasspa
dc.subjectControl de calidadspa
dc.subject.proposalBioimpedanciases-ES
dc.subject.proposalespectroscopiaes-ES
dc.subject.proposalamplificadores de instrumentaciónes-ES
dc.subject.proposalMatlabes-ES
dc.subject.proposalProtocoloes-ES
dc.titleSystem Based on the Technique of Spectroscopy for Measurement of Bioimpedancias for Samples in Tissues of Fishen-US
dc.titleSistema Basado en la Técnica de Espectroscopía por Medición de Bioimpedancias para Muestras en Tejidos de Pescadoes-ES
dc.type.coarhttp://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.localArtículo Revisado por Pares Académicoses-ES